BHJCM - UNIVERSAL PAPER DEVELOPER
- MSDS: BHJCM
- Manufacturer: ILFORD PHOTO CORP
- Product Name: UNIVERSAL PAPER DEVELOPER
- National Stock Number: 6750-00D002555
Product Identification
Product ID:UNIVERSAL PAPER DEVELOPER
MSDS Date:11/29/1988
FSC:6750
NIIN:00D002555
MSDS Number: BHJCM
Responsible Party
PARAMUS, NJ 07653
US
Emergency Phone: 800-888-8372
Info Phone: 201-265-6000
Cage: 64145
Contractor
Telephone: 201-265-6000
Cage: 64145
Ingredients
HYDROQUINONE (SARA III)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: 1-5%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 5-10%
POTASSIUM BROMIDE
CAS: 7758-02-3
RTECS: TS7650000
Fraction By Weight: <1%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 10-15%
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 70-75%
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRODUCT MAY CAUSE EYE, SKIN AND G/I OR
RESPIRATORY TRACT IRRITATION. IT IS CONSIDERED A LOW HAZARD FOR
NORMAL INDUSTRIAL HANDLING.
Explanation of Carcinogenicity:IARC REPORTS HYDROQUINONE 'INSUFFICIENT
EVIDENCE TO CLASSIFY
Effects of Overexposure:EYE:CAUSES IRRITATION SKIN:CAUSES IRRITATION,
AND MAY SENSITIZE AN ALLERGIC REACTION. INHALED:UNLIKELY
EXPOSURE,MAY CAUSE IRRITATION. INGESTED:MAY BE HARMFUL IF
SWALLOWED. HMIS:MAY CAUSE G/I IRRITA
TION,NAUSEA,VOMITING,PALLOR,TINNITIS,DIZZINESS, OR INCREASED
RESPIRATORY RATE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:REMOVE CONTAMINATED
CLOTHING AND LAUNDER BEFORE REUSE. WASH SKIN WITH SOAP AND WATER.
INHALED: REMOVE TO FRESH AIR. INGESTED:IF CONSCIOUS,GIVE 1-2
GLASSES OF WATE R AND IMMEDIATELY INDUCE VOMITING. (NOTHING BY
MOUTH IF UNCONSCIOUS.) GET IMMEDIATE MEDICAL CARE. IF ANY
IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL CARE.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SOURCE OF FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
Accidental Release
Spill Release Procedures:RECOVER AS LIQUID OR MOP UP WITH
CLOTH,PAPER,ETC.
Neutralizing Agent:NONE
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL VENTILATED
AREA. KEEP TIGHTLY CLOSED WHEN NOT IN USE. KEEP AWAY FROM STRONG
ACIDS AND OXIDIZERS.
Other Precautions:READ LABEL AND FOLLOW DIRECTIONS.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR IF PEL/TLV IS EXCEEDED OR DISCOMFORT IS EXPERIENCED.
Ventilation:NORMAL ROOM VENTILATION. MAY BE SUPPLEMENTED WITH LOCAL
EXHAUST IF DESIRED.
Protective Gloves:RUBBER,VINYL,OTHER IMPERVIOUS
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER. USE APRON
AND FACE SHIELD WHEN POURING LIQUIDS OR IF SPLASHING IS LIKELY.
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT.
Supplemental Safety and Health
ILFORD STOCK NUMBER MG9112399 TO MAKE 1 GALLON AND MG9112401 TO MAKE 10
GALLONS. COD = 62 GM OXYGEN/L. ALSO SEE ADD.DATA.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:AS WATER
Vapor Density:AS WATER
Spec Gravity:1.208
pH:10.8
Evaporation Rate & Reference:AS WATER
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID, NO ODOR
Percent Volatiles by Volume:75
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG ACIDS
Stability Condition to Avoid:NO INFORMATION GIVEN BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
SULFUR DIOXIDE, NITROGEN OXIDES
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
MFR SUGGESTS FLUSH TO ACID-FREE SEWER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.